Extending the utility of noise equivalent quanta (NEQ) for dynamic range measurement in imaging systems
Author(s)
Uwe Artmann | Image Engineering GmbH & Co KG
Abstract
This paper investigates the application of Noise Equivalent Quanta (NEQ) as a comprehensive metric for assessing dynamic range in imaging systems. Building on previous work that demonstrated NEQ’s utility in characterizing noise and resolution trade-offs in imaging systems using the Dead Leaves technique, this study seeks to validate the use of NEQ for dynamic range characterization, especially in high-dynamic-range (HDR) systems where conventional metrics may fall short.
Extending the utility of noise equivalent quanta (NEQ) for dynamic range measurement in imaging systems
Description
Date and Location: 2/3/2025 | 04:50 PM - 05:10 PM | Grand Peninsula A
Primary Session Chair:
Patrick Denny | University of LImerick
Session Co-Chair: